DiTeSt Medium Temperature Sensing Cable


FOR TEMPERATURES UP TO 150°C

Distributed Fiber optic temperature sensor  for Civil, geotechnical monitoring and leak detection

Reliable and versatile cable for easy installation.

Small size and fast reaction to temperature changes.

 


The DiTeSt Medium Temperature Sensing cable is a unique sensor for the evaluation of distributed temperature over several kilometers and up to 150°C

 

The  DiTeSt Medium Temperature Sensing cable is used in a wide range of applications that require distributed temperature sensing, such as temperature monitoring of concrete in massive structures, waste disposal sites, on- and off-shore sites in gas and oil industry, hot spots, cold spots and leakage detection of flow lines and reservoirs, building installations, just to name a few.

 

The DiTeSt Medium Temperature Sensing cable is a small fiber optic cable, armored with stainless steel loose tube gel filled, stainless steel strength members and TPE outer sheath. The central loose tube, with optimized fiber excess length, is hermetically sealed and contains 2 mid temperature dual layer acrylate fibers for increased micro bending performance.

 

This sensor is particularly suitable for outdoors and harsh environment applications with different methodology of installation: direct burial in the ground or concrete, clamped to a pipe, anchored or glued.

 

Thanks to the special package design, the DiTeSt Medium Temperature Sensing cable offers high tensile strength, crush resistance, lateral water tightness, chemical and abrasion resistance and excellent rodent protection.

 

The DiTeSt Medium Temperature Sensing cable is fully compatible with the DiTeSt system and all its accessories.

 

Specifications

 

 

  Temperature range  
  Operating temperature:   -40 °C to +150 °C
  Storage temperature:   -40 °C to +150 °C
  Installation temperature:   -10 °C to +150 °C
  Short-term temperature (max 1 h):   -50°C to +180°C 

 

 

  Technical Data  
  Outer diameter:   3.8 mm
  Weight:   28 kg/km
  Max crush resistance:   900 N/cm
  Max tensile strength:   1500 N (installation)
  Max tensile strength:   1100 N (operation)
  Min bending radius:   80 mm (with tensile)
  Min bending radius:   60 mm (without tensile)
  Hydrostatic pressure:   300 kPa (bar)

 

 

  Fiber Types  
  Fiber support:   SMF 9 / 125 µm ITU-T G.652.D compliant
  Fiber attenuation (cabled @ 20 °C):   ≤ 0.36 dB @ 1310 nm;  ≤ 0.25 dB @ 1550 nm
  Number of fiber:   2


 

Ordering Info

 

Accessories:

  •     Cable termination with connectors
  •     Junction box
  •     Splice box
  •     SMF ITU-T G.657 compliant upon request