Direct & Inverted Pendulum Reading Table


EASY MONITORING

LONG-TERM RELIABILITY

ACCURACY GREATER THAN WITH GEODESIC SURVEYS

Pendulums are designed to accurately measure the relative internal horizontal displacements of points along a true vertical line

 


Direct pendulum

 

The direct pendulum consists of a wire suspended from the upper point and a reading station fixed to the structure at the lower point. The wire is tensioned by a suspended weight submerged in a damper tank.

 

Inverted pendulum

 

The fixed end of the inverted pendulum is grouted at the lower point of the system. A float tensions the wire vertically. When anchored to a fixed point in the foundation, it measures absolute displacement of points along the wire.

 

The monitoring of the wire position for both direct and inverted pendulums can be done manually and/or electrically with a remote readout unit (ref: Model RxTx Telependulum – see separate brochure). The method of reading depends upon the concept of monitoring, the expected values of movements, and the accuracy required.

 

Manual Reading Options and Interpretations

 

A) Sighting reading table Model 76

 

To take a reading, the operator aligns the cursors with their respective sights and with the pendulum wire. The positions of the cursors are read directly off the scale and the vernier cursor. The readings are converted to wire displacement values using the chart provided with each reading station.

 

B) Optical coordinoscope Model MVR

 

The setup consists of a reference base permanently installed at the reading point. The coordinoscope is then installed on its reference section respectively at X and Y axes on the base frame. Measurements are taken by focusing or aiming the lens at the pendulum wire and by reading the current lateral displacement on the vernier.

 

Specifications

 

   PENDULUM COMPONENTS                                                                                                
  Direct pendulum 

  Stainless steel or invar wire

  Upper hook and vee-shaped guide bracket

  Wire tensioning weight and hook

   Damper tank

  Inverted pendulum

  Wire (same as for direct pendulum)

  Anchoring weight

  PVC float and float tank assembly

 

 

  MODEL 76  
  Range   ±15 mm
  Resolution   0.1 mm
  Accuracy   0.5 mm
  Reading station     component                                      Stainless steel table (includes scales, cursors, sights and chart for evaluating wire position)

 

 

  MODEL MVR                                                                     
  Range   400 mm
  Accuracy   0.02 mm
  Focal range   ±50 mm
  Overall dimensions   500 x 500 mm

 


Ordering Info

 

Please specify:

  •     Type of pendulum
  •     Wire length
  •     Manual or remote reading station

 

Optional accessories:

  •     Mounting brackets
  •     Creep test kit for long term testing at constant pressure